ASTM F2413 05 PDF

1 | Page. ASTM. American Society For Testing and Materials. F Standard Specification for Performance Requirements for Foot. Protection. Abstract. Learn about ASTM footwear standards and how to properly read a label. The 11 after the dash signifies the footwear meets the ASTM F or F ASTM F EH Overshoes are made from yellow ozone resistant rubber that’s % waterproof.

Author: Dosida Grogar
Country: Haiti
Language: English (Spanish)
Genre: Career
Published (Last): 21 February 2006
Pages: 412
PDF File Size: 7.21 Mb
ePub File Size: 8.89 Mb
ISBN: 957-7-69125-674-4
Downloads: 36472
Price: Free* [*Free Regsitration Required]
Uploader: Tojashura

Axtm letters PT indicate the protective toe section of the standard. I’m a client Email. Electrical hazard EH footwear is manufactured with non-conductive electrical shock resistant soles and heals. It also identifies the existence of impact resistance Ithe impact resistance ast, 75 or 50 foot-poundscompression resistance C and the compression resistance rating 75 or 50 which correlates to pounds and pounds of compression respectively.

The ANSI standard incorporates a coding system that manufacturers use to identify the portions of the standard with which the footwear complies.

It is not the intention of this specification to serve as a detailed manufacturing or purchasing specification, but can be referenced in purchase contracts to ensure that minimum performance requirements are met.

You are commenting using your Facebook account. The purpose of this standard is to summarize the requirements for certifying protective footwear by independent, third party laboratories. Safety and client access have no downtime.

Then the requirements of additional sections such as electrical hazard protection, conductive protection and protection against punctures and penetration can be met. Standard specification for performance requirements for protective safety toecap footwear. All footwear manufactured to ANSI specifications will be marked with the specific portion of the standard with which it complies. Any changes to the original components of safety toe footwear, such as replacing or adding foot beds or inserts, could cause failure to any or all parts of the ASTM standard invalidates the safety marking.

All footwear manufactured to the ASTM specification must be marked with the specific portion of the standard with which it complies. Lines 3 and 4 are f2143 to reference additional sections in the standard.

  FERREL G STREMLER INTRODUCTION TO COMMUNICATION SYSTEMS PDF

Electrical hazard EH footwear is manufactured with non-conductive, electrical shock-resistant soles zstm heels. One shoe of each pair must be clearly and legibly marked e. The footwear must have a lower limit of electrical resistance of 10 6 ohms and satm upper limit of 10 8 ohms.

Email required Address never made public. Cancel reply Enter your comment here Published by Jack Benton. The footwear must withstand a minimum force of pounds. Conductive Cd footwear is intended to provide protection for the wearer against hazards that may result from static electricity buildup and to reduce the possibility of ignition of explosives or volatile chemicals.

ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. Line four is used only when more than three sections of the standard apply to the footwear.

ASTM F2413-05 EH Footwear Overshoes

It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. Most manufacturers of add-on devices have submitted their products to independent laboratories for testing. The electrical resistance must range between zero andohms. The puncture resistant footwear must show no signs of cracking after being subjected to 1. The purpose of metatarsal footwear is to prevent or reduce the severity of injury to the metatarsal and toe areas.

The purpose of sole puncture resistant PR protective footwear is to reduce the possibility of injury caused by sharp objects that may penetrate the soles of the footwear.

Notify me of new comments via email. One shoe of each ast must be clearly and legibly marked stitched in, stamped, pressure sensitive label, or a combination of these methods on the inside or outside surface of the tongue, gusset, shaft or quarter lining.

This xstm is an integral and permanent part of the footwear. All footwear manufactured to this ASTM specification must be marked with the specific portion of the standard with which it complies.

Post was not sent – check your email addresses! Instead, this specification can be 50 in purchase contracts to ensure that minimum performance requirements are met.

  GUHRING SUPERLINE 2012 PDF

One shoe of each pair must be clearly and legibly marked stitched in, stamped on, pressure sensitive label, etc. The identification code must qstm legible printed, stamped, stitched, etc. Static dissipative SD footwear is designed to reduce the accumulation of excess static electricity by conducting body charge to ground while maintaining a sufficiently high level of resistance.

OSHA & ASTM Protective Footwear Requirements – EHS Safety News America

This specification covers the minimum design, performance, testing, and classification requirements, and prescribes fit, function, and performance criteria for footwear designed to be worn to provide protection against a variety of workplace hazards that can potentially result in injury. The electrical resistance must range between zero astohms. This is followed by the last two digits of the year of the standard with which the footwear meets compliance This data and its results astk be obtained upon request.

PR CS Lines 3 and 4 are used to identify footwear made to offer protection from other specific types of axtm referenced in the standard. The footwear must facilitate electrical conductivity and the transfer of static electricity build-up from the wearer to the ground. This line identifies the gender [M Male or F Female ] of the user.

This abstract is a brief summary of the referenced standard. The metatarsal designation Mt and rating i. The puncture resistant device must be an integral part of the footwear and must be constructed into the shoe during the manufacturing process. Conductive Cd footwear is intended to protect the wearer in an environment where the accumulation f24113 static f24133 on the body is a hazard.

It is not the intention of this specification to serve as a detailed manufacturing or purchasing specification. This line identifies the ANSI standard. It allows employers to use PPE constructed in accordance with any of three national consensus standards the two most recent and the incorporated reference in the current standards.